dt-bindings: iio: pressure: honeywell,mprls0025pa.yaml add pressure-triplet
Change order of properties in order for the end user to hopefully ignore pmin-pascal and pmax-pascal which are superseded by pressure-triplet. Add pressure-triplet property which automatically initializes pmin-pascal and pmax-pascal inside the driver. Rework honeywell,pmXX-pascal requirements based on feedback from Jonathan and Conor. Co-developed-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Link: https://lore.kernel.org/r/20231229092445.30180-3-petre.rodan@subdimension.ro Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
7b34e1e330
commit
0181749d4e
1 changed files with 46 additions and 18 deletions
|
@ -19,14 +19,17 @@ description: |
|
|||
calls them "mpr series". All of them have the identical programming model and
|
||||
differ in the pressure range, unit and transfer function.
|
||||
|
||||
To support different models one need to specify the pressure range as well as
|
||||
the transfer function. Pressure range needs to be converted from its unit to
|
||||
pascal.
|
||||
To support different models one need to specify its pressure triplet as well
|
||||
as the transfer function.
|
||||
|
||||
For custom silicon chips not covered by the Honeywell MPR series datasheet,
|
||||
the pressure values can be specified manually via honeywell,pmin-pascal and
|
||||
honeywell,pmax-pascal.
|
||||
The minimal range value stands for the minimum pressure and the maximum value
|
||||
also for the maximum pressure with linear relation inside the range.
|
||||
|
||||
The transfer function defines the ranges of numerical values delivered by the
|
||||
sensor. The minimal range value stands for the minimum pressure and the
|
||||
maximum value also for the maximum pressure with linear relation inside the
|
||||
range.
|
||||
sensor.
|
||||
|
||||
Specifications about the devices can be found at:
|
||||
https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/
|
||||
|
@ -54,14 +57,6 @@ properties:
|
|||
If not present the device is not reset during the probe.
|
||||
maxItems: 1
|
||||
|
||||
honeywell,pmin-pascal:
|
||||
description:
|
||||
Minimum pressure value the sensor can measure in pascal.
|
||||
|
||||
honeywell,pmax-pascal:
|
||||
description:
|
||||
Maximum pressure value the sensor can measure in pascal.
|
||||
|
||||
honeywell,transfer-function:
|
||||
description: |
|
||||
Transfer function which defines the range of valid values delivered by the
|
||||
|
@ -72,17 +67,50 @@ properties:
|
|||
enum: [1, 2, 3]
|
||||
$ref: /schemas/types.yaml#/definitions/uint32
|
||||
|
||||
honeywell,pressure-triplet:
|
||||
description: |
|
||||
Case-sensitive five character string that defines pressure range, unit
|
||||
and type as part of the device nomenclature. In the unlikely case of a
|
||||
custom chip, unset and provide pmin-pascal and pmax-pascal instead.
|
||||
enum: [0001BA, 01.6BA, 02.5BA, 0060MG, 0100MG, 0160MG, 0250MG, 0400MG,
|
||||
0600MG, 0001BG, 01.6BG, 02.5BG, 0100KA, 0160KA, 0250KA, 0006KG,
|
||||
0010KG, 0016KG, 0025KG, 0040KG, 0060KG, 0100KG, 0160KG, 0250KG,
|
||||
0015PA, 0025PA, 0030PA, 0001PG, 0005PG, 0015PG, 0030PG, 0300YG]
|
||||
$ref: /schemas/types.yaml#/definitions/string
|
||||
|
||||
honeywell,pmin-pascal:
|
||||
description:
|
||||
Minimum pressure value the sensor can measure in pascal.
|
||||
|
||||
honeywell,pmax-pascal:
|
||||
description:
|
||||
Maximum pressure value the sensor can measure in pascal.
|
||||
|
||||
vdd-supply:
|
||||
description: provide VDD power to the sensor.
|
||||
|
||||
required:
|
||||
- compatible
|
||||
- reg
|
||||
- honeywell,pmin-pascal
|
||||
- honeywell,pmax-pascal
|
||||
- honeywell,transfer-function
|
||||
- vdd-supply
|
||||
|
||||
oneOf:
|
||||
- required:
|
||||
- honeywell,pressure-triplet
|
||||
- required:
|
||||
- honeywell,pmin-pascal
|
||||
- honeywell,pmax-pascal
|
||||
|
||||
allOf:
|
||||
- if:
|
||||
required:
|
||||
- honeywell,pressure-triplet
|
||||
then:
|
||||
properties:
|
||||
honeywell,pmin-pascal: false
|
||||
honeywell,pmax-pascal: false
|
||||
|
||||
additionalProperties: false
|
||||
|
||||
examples:
|
||||
|
@ -99,8 +127,8 @@ examples:
|
|||
reset-gpios = <&gpio3 19 GPIO_ACTIVE_HIGH>;
|
||||
interrupt-parent = <&gpio3>;
|
||||
interrupts = <21 IRQ_TYPE_EDGE_RISING>;
|
||||
honeywell,pmin-pascal = <0>;
|
||||
honeywell,pmax-pascal = <172369>;
|
||||
|
||||
honeywell,pressure-triplet = "0025PA";
|
||||
honeywell,transfer-function = <1>;
|
||||
vdd-supply = <&vcc_3v3>;
|
||||
};
|
||||
|
|